C0216 (bizhub 558/458)

You are here:

Contents

Trouble typeC0216: External LCT up/down abnormality (When LU-207 or LU-302 is installed)
RankB
Trouble detection conditionThe LU upper limit sensor (PS2) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationLCT
Relevant electrical parts• LU upper limit sensor (PS2)
• LU lift-up motor (M1)
• LU drive board (LUDB)

 Procedure

  1. Check the connector between M1-LUDB CN3 for proper connection and correct as necessary.
  2. Check the connector of M1 for proper drive coupling and correct as necessary.
  3. Check the connector between PS2-relay CN406 (LU-207), Cn3 (LU-302)-LUDB CN5 for proper connection and correct as necessary.
  4. PS2 I/O check, sensor check
    • Control signal: LUDB CN5-3 (ON)
    • Location of electrical component: LU-207/LU-302 4-G
  5. M1 operation check
    • Control signal: LUDB CN3-4 (ON)
    • Location of electrical component: LU-207/LU-302 3-G
  6. Replace M1. (LU-207 Part# A00JR74900 / LU-302 Part# A00JR74900)
  7. Replace LUDB. (LU-207 Part# A87VH01000 / LU-302 Part# A87VH01000)

NOTICE

  • Link to the wiring diagram (LU-207)
  • Link to the wiring diagram (LU-302)