How Can We Help?

C0216 (bizhub 650i/550i/450i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC0216: External LCT up/down abnormality (When LU-207 or LU-302 is installed)
RankB
Trouble detection conditionThe LU upper limit sensor (PS2) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationLCT
Relevant electrical parts-LU upper limit sensor (PS2)
-LU lift-up motor (M1)
-LU drive board (LUDB)

Procedure

  1. Check the connector between M1-LUDB CN3 for proper connection and correct as necessary.
  2. Check the connector of M1 for proper drive coupling and correct as necessary.
  3. Check the connector between PS2-relay CN406 (LU-207), relay CN3 (LU-302)-LUDB CN5 for proper connection and correct as necessary.
  4. PS2 I/O check, sensor check
    • Control signal: LUDB CN5-3 (ON)
    • Location of electrical component: LU-207/LU-302 4-G
  5. M1 load check
    • Check code: 23
    • Multi code: 8
    • Control signal: LUDB CN3-4 (ON)
    • Location of electrical component: LU-207/LU-302 3-G
  6. Replace M1. (LU-207 / LU-302) (Part# A00JR74900)
  7. Replace LUDB. (LU-207 / LU-302)
    LU-207 (Part# A87VH01000)
    LU-302 (Part# A87VH01000)

(Link to the Field Service Manual)