C0216 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0216: External LCT up/down abnormality (When LU-205 or LU-303 is installed) |
Rank | B |
Trouble detection condition | The LU upper limit sensor (PS2) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | LCT |
Relevant electrical parts | -LU upper limit sensor (PS2) -LU lift-up motor (M1) -LU drive board (LUDB) |
Procedure
- Check the connector between M1-LUDB CN3 for proper connection and correct as necessary.
- Check the connector of M1 for proper drive coupling and correct as necessary.
- Check the connector between PS2-relay CN406-LUDB CN5 for proper connection and correct as necessary.
- PS2 I/O check, sensor check
- Control signal: LUDB CN5-3 (ON)
- Location of electrical component: LU-205/LU-303 4-G
- M1 load check
- Check code: 23
- Multi code: 8
- Control signal: LUDB CN3-4 (ON)
- Location of electrical component: LU-205/LU-303 3-G
- Replace M1. (LU-205 / LU-303) (Part# A00JR74900)
- Replace LUDB. (LU-205 / LU-303)
LU-205 (Part# A8H6H00100)
LU-303 (Part# A8H6H00100)