C0216 (bizhub C658/C558/C458)
Contents
| Trouble type | C0216: External LCT up/down abnormality (When LU-207 or LU-302 is installed) | 
| Rank | B | 
| Trouble detection condition | The LU upper limit sensor (PS2) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. | 
| Trouble isolation | LCT | 
| Relevant electrical parts | •LU upper limit sensor (PS2) • LU lift-up motor (M1) • LU drive board (LUDB) | 
Procedure
- Check the connector between M1-LUDB CN3 for proper connection and correct as necessary.
- Check the connector of M1 for proper drive coupling and correct as necessary.
- Check the connector between PS2-relay CN406 (LU-207), Cn3 (LU-302)-LUDB CN5 for proper connection and correct as necessary.
- PS2 I/O check, sensor check- Control signal: LUDB CN5-3 (ON)
- Location of electrical component: LU-207/LU-302 4-G
 
- M1 operation check- Control signal: LUDB CN3-4 (ON)
- Location of electrical component: LU-207/LU-302 3-G
 
- Replace M1. (LU-207 Part# A00JR74900 / LU-302 Part# A00JR74900)
- Replace LUDB. (LU-207 Part# A87VH01000/ LU-302 Part# A87VH01000)
NOTICE
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.8.13 (Link to the Field Service Manual)