C0301 (bizhub 754e/654e)

You are here:

Contents

Trouble typeSuction fans failure to turn
Trouble codeC0301
RankB
Detection timingThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Suction fan (FM1)
• Paper feed/transport drive board (PFTDB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM1-relay CN278-relay CN271B-PFTDB CN10 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM1 operation checkPFTDB CN10-3 (REM)PFTDB CN10-5 (LOCK)5-P
4Replace FM1 (Part# 9313100072 )
5PFTDB ICP2 conduction check
6Replace PFTDB (Part# A2X0H00202 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.