Trouble typeC0301: Suction fan failure to turn
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts-Suction fan (FM1)
-Paper feed/transport drive board (PFTDB)

 Procedure

  1. Check the connector between FM1-relay CN278-relay CN300-relay CN271B-PFTDB CN8 for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. FM1 load check
    • Check code: 42
    • Multi code: 2
    • Control signal: PFTDB CN8-3 (REM), PFTDB CN8-5 (LOCK)
    • Location of electrical component: 6-P
  4. Replace FM1. (Part# 9313100072)
  5. PFTDB F2 conduction check
  6. Replace PFTDB. (Part# A795H00200)