How Can We Help?

C1004 (bizhub 554e/454e)

You are here:

Contents

Trouble type FNS communication error
Trouble code C1004
Rank C
Detection timing <When FS-533, FS-534 or FS-535 is installed> When the FS control board (FSCB) is receiving data, a communication error is detected.

<When JS-506 is installed>
When the JS control board (JSCB) is receiving data, a communication error is detected.
Trouble isolation
Relevant electrical parts <When FS-533, FS-534 or FS-535 is installed> FS control board (FSCB)

<When JS-506 is installed>
JS control board (JSCB)

  (2)Procedure When FS-533, FS-534 or FS-535 is installed

Step Action Control signal Location of electrical components
1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
2 Rewrite the firmware.
3 Replace FSCB (FS-533/FS-534/FS-535) FSCB
FS-533 (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))
FS-534 (Part# A3EPPPBE01)
FS-535 (Part# A2Y1H10002)

When JS-506 is installed

Step Action Control signal Location of electrical components
1 Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
2 Rewrite the firmware.
3 Replace JSCB JSCB JS-506 (Part# A2YVH10102)

Document Information ID D0001134257 Revise ID R000004