How Can We Help?

C1014 (bizhub 558/458/368/308)

You are here:

Contents

Trouble typeC1014: Finisher communication error (Finisher detection)
RankC
Trouble detection condition<When FS-533, FS-536, FS-536SD, FS-537, or FS-537SD is installed>
When a communication error is detected between the MFP board (MFPB) and the FS control board (FSCB).
<When JS-506 is installed>
When a communication error is detected between the MFP board (MFPB) and the JS control board (JSCB).
Trouble isolation
Relevant electrical parts<When FS-533, FS-536, FS-536SD, FS-537, or FS-537SD is installed> 
• FS control board (FSCB) 
• MFP board (MFPB)
<When JS-506 is installed>JS control board (JSCB)

 Procedure

 When FS-533, FS-536, FS-536SD, FS-537, or FS-537SD is installed

  1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
  2. Rewrite the firmware.
  3. Replace FSCB. (FS-533 (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2)) / FS-536/FS-536SD Part# A87GPP0V00 / FS-537/FS-537SD Part# A87HPP9M01)
  4. PKCB ICP1 conduction check.
  5. PIDB ICP1 conduction check.
  6. Replace MFPB. (bizhub 368/308 Part# A9HJH02102 / bizhub 558/458 (558 Part# A9HGH02102 / 458 Part# A9HHH02102))

 When JS-506 is installed

  1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
  2. Rewrite the firmware.
  3. Replace JSCB. (Part# A2YVH10102)