How Can We Help?

C1082 (bizhub 558/458/368/308)

You are here:

Contents

Trouble typeC1082: SD communication error (SD detection)
RankC
Trouble detection condition<When FS-536SD or FS-537SD is installed> 
When a communication error is detected between the FS control board (FSCB) and the SD control board (SDCB).
Trouble isolationCenter Stapling/Half-Fold/Tri-Fold
Relevant electrical parts• SD control board (SDCB) 
• FS control board (FSCB)

 Procedure

  1. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.
  2. Rewrite the firmware.
  3. Replace SDCB. (FS-536/FS-536SD  FS-537/FS-537SD) (Part# A3ERPP6J03)
  4. Replace FSCB. (FS-536/FS-536SD Part# A87GPP0V00 / FS-537/FS-537SD Part# A87HPP9M01)

Please review all Part Numbers for accuracy and cur