C1103 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C1103: Alignment plate motor/Fr malfunction (When FS-533, FS-534 or FS-534SD is installed) |
Rank | B |
Trouble detection condition | <When FS-533 is installed> -The alignment plate home sensor/F (PS108) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. -The alignment plate home sensor/F (PS108) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/F (M105) is turned ON to return the plate to the home position. |
<When FS-534 or FS-534SD is installed> -The alignment plate/F home sensor (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. -The alignment plate/F home sensor (PS12) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/Front (M7) is turned ON to return the plate to the home position.The alignment plate/F does not reach the specified position within the set period of time. | |
Trouble isolation | – |
Relevant electrical parts | <When FS-533 is installed> -Alignment motor/F (M105) -Alignment plate home sensor/F (PS108) -FS control board (FSCB) |
<When FS-534 or FS-534SD is installed> -Alignment motor/Front (M7) -Alignment plate/F home sensor (PS12) -FS control board (FSCB) |
Procedure
When FS-533 is installed
- Check the connector between M105-FSCB CN102 for proper connection and correct as necessary.
- Check the connector of M105 for proper drive coupling, and correct as necessary.
- Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary.
- PS108 I/O check, sensor check
- Control signal: FSCB CN102
- Location of electrical component: FS-533 7-J
- M105 operation check
- Control signal: FSCB CN102
- Location of electrical component: FS-533 7-J
- Replace M105. (Part# A2YUPPW600)
- FSCB CP105 conduction check
- Replace FSCB. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2)
NOTICE
- Link to the wiring diagram (FS-533)
When FS-534 or FS-534SD is installed
- Check the connector between M7-FSCB J4 for proper connection and correct as necessary.
- Check the connector of M7 for proper drive coupling and correct as necessary.
- Check the connector between PS12-FSCB J4 for proper connection and correct as necessary.
- PS12 I/O check, sensor check
- Control signal: FSCB J4<B>-4 (ON)
- Location of electrical component: FS-534 13-C
- M7 operation check
- Control signal: FSCB J4<A>-5 to 8
- Location of electrical component: FS-534 11-C to D
- Replace M7. (Part# A3EPPP5500)
- Replace FSCB. (Part# A3EPPPBE01)
NOTICE
- Link to the wiring diagram (FS-534)
K.3.8.4 (Link to the Field Service Manual)