C1103 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When FS-539 or FS-539SD is installed
Contents
Trouble type | C1103: Alignment motor/Fr drive malfunction (When FS-539 or FS-539SD is installed) |
Rank | B |
Trouble detection condition | -The alignment plate home sensor/Fr (PS12) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. -The alignment plate home sensor/Fr (PS12) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/Fr (M7) is energized when the plate returned to the home position. -The alignment plate/Fr does not reach the specified position within the set period of time. |
Trouble isolation | – |
Relevant electrical parts | -Alignment motor/Fr (M7) -Alignment plate home sensor/Fr (PS12) -FS control board (FSCB) |
Procedure
- Check the connector between M7-relay CN13-FSCB J4 for proper connection and correct as necessary.
- Check the connector of M7 for proper drive coupling and correct as necessary.
- Check the connector between PS12-FSCB J4 for proper connection and correct as necessary.
- PS12 I/O check, sensor check
- Control signal: FSCB J4<B>-4 (ON)
- Location of electrical component: FS-539/FS-539SD 14-C
- M7 operation check
- Control signal: FSCB J4<A>-5 to 8
- Location of electrical component: FS-539/FS-539SD 13 to 14-C
- Replace M7. (Part# A3EPPP5500)
- Replace FSCB. (Part# AAR4PP8201)
When FS-540 or FS-540SD is installed
Contents
Trouble type | C1103: Alignment motor/Fr drive malfunction (When FS-540 or FS-540SD is installed) |
Rank | B |
Trouble detection condition | -The alignment plate home sensor/Fr (PS9) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. -The alignment plate home sensor/Fr (PS9) is not turned ON (blocked) after the set period of time has elapsed after the alignment motor/Fr (M14) is energized when the plate returned to the home position. -The alignment plate/Fr does not reach the specified position within the set period of time. |
Trouble isolation | – |
Relevant electrical parts | -Alignment motor/Fr (M14) -Alignment plate home sensor/Fr (PS9) -FS control board (FSCB) |
Procedure
- Check the connector between M14-relay CN5-FSCB J18 for proper connection and correct as necessary.
- Check the connector of M14 for proper drive coupling and correct as necessary.
- Check the connector between PS9-relay CN5-FSCB J18 for proper connection and correct as necessary.
- PS9 I/O check, sensor check
- Control signal: FSCB J18-10 (ON)
- Location of electrical component: FS-540/FS-540SD 6-D
- M14 operation check
- Control signal: FSCB J18-1 to 4
- Location of electrical component: FS-540/FS-540SD 5-D
- Replace M14. (Part# A87HPPAD00)
- Replace FSCB. (Part# AAR5PPD401)