How Can We Help?

C1105 (bizhub C554e/C454e)

You are here:

(1)Contents

Trouble typeBundle eject motors drive malfunction <When FS-534 is installed>
Paper output roller motors drive malfunction <When FS-535 is installed>
Trouble codeC1105
RankB
Detection timing<When FS-534 is installed>
• The gripper home position sensor (PS18) does not block even after the set period of time has elapsed after the gripper position detection sensor (PS19) unblocked.
• The gripper position detection sensor (PS19) does not block even after the set period of time has elapsed after it unblock.
• The gripper position detection sensor (PS19) does not block even after the set period of time has elapsed after the gripper home position sensor (PS18) unblocked.
• The gripper home position sensor (PS18) does not block even after the set period of time has elapsed after the bundle eject motor (M10) unblocked.
• The gripper home position sensor (PS18) and the gripper position detection sensor (PS19) are blocked at the same time.

<When FS-535 is installed>
The paper output roller home sensor (PS10) is not blocked or unblocked even after the set period of time has elapsed after the paper output roller motor (M6) is turned ON.
Trouble isolation
Relevant electrical parts<When FS-534 is installed>
• Bundle eject motor (M10)
• Gripper home position sensor (PS18)
• Gripper position detection sensor (PS19)
• FS control board (FSCB)
<When FS-535 is installed>
• Paper output roller motor (M6)
• Paper output roller home sensor (PS10)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the motor and sensor connectors for proper connection, and correct as necessary.
2Check the connector of M10 for proper drive coupling, and correct as necessary.
3PS18 I/O check, sensor checkFSCB J13-13 (ON)FS-534 7-C
4PS19 I/O check, sensor checkFSCB J12-3 (ON)FS-534 7-C
5M10 operation checkFSCB J13-1 to 2FS-534 8-C to D
6Replace M10 (Part# A87GPP1400)
7Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M6-FSCB CN60 for proper connection and correct as necessary.
2Check the connector of M6 for proper drive coupling, and correct as necessary.
3Check the connector between PS10-relay CN211-FSCB CN21 for proper connection and correct as necessary.
4PS10 I/O check, sensor checkFSCB CN21-3 (ON)FS-535 6-L
5M6 operation checkFSCB CN60-9 to 12FS-535 16-D
6Replace M6 (Part# A2Y1M10200)
7FSCB ICP19 conduction check
8Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.9 (Link to the Field Service Manual)