How Can We Help?

C1106 (bizhub C554/C454)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeStapler movement motors malfunction
Trouble codeC1106
RankB
Detection timing<When FS-533 is installed>
-The stapler home sensor (PS110) is not unblocked after the laps of given time after it started operating from the home position.
-The stapler home sensor (PS110) is not unblocked after the laps of give time after the stapler movement motor (M107) turned ON when it returned to the home position.
<When FS-534 is installed>
-The stapler home position sensor (Rear) (PS23) is not blocked or unblocked even after the set period of time has elapsed after the side stapler movement motor (M13) turned ON.
-The stapler does not reach the specified position within the set period of time.
<When FS-535 is installed>
The stapler position sensor/1/2/3/4 (PS50/PS/51/PS52/PS53) is blocked or unblocked even after the set period of time has elapsed after the stapler movement motor (M13) is turned ON.
Trouble isolationStaple
Relevant electrical parts<When FS-533 is installed>
-Stapler movement motor (M107)
-Stapler home sensor (PS110)
-Stapler relay board (STREYB)
-FS control board (FSCB)
<When FS-534 is installed>
-Side stapler movement motor (M13)
-Stapler home position sensor (Rear) (PS23)
-FS control board (FSCB)
<When FS-535 is installed>
-Stapler movement motor (M13)
-Stapler position sensor/1 (PS50)
-Stapler position sensor/2 (PS51)
-Stapler position sensor/3 (PS52)
-Stapler position sensor/4 (PS53)
-FS control board (FSCB)

(2)Procedure When FS-533 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M107-STREYB CN123 for proper connection, and correct as necessary.
2Check the connector of M107 for proper drive coupling, and correct as necessary.
3Check the connector between PS110-FSCB CN110 for proper connection, and correct as necessary.
4PS110 I/O check, sensor checkFSCB CN110FS-533 8-D to E
5M107 operation checkSTREYB CN123-5 to 8FS-533 5-L
6Replace M107 (Part# A2YUPPT400)
7Replace STREYB (Part# A2YUPPG700)
8FSCB CP107 conduction check
9Replace FSCB (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))

When FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M13-relay CN3-FSCB J11 for proper connection, and correct as necessary.
2Check the connector of M13 for proper drive coupling, and correct as necessary.
3Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary.
4PS23 I/O check, sensor checkFSCB J11<B>-3 (ON)FS-534 4-C
5M13 operation checkFSCB J11<A>-1 to 4FS-534 4-C to D
6Replace M13 (Part# A3EPPP9104)
7Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical components
1Check the motor and sensor connectors for proper connection, and correct as necessary.
2Check the connector of M13 for proper drive coupling, and correct as necessary.
3PS50 I/O check, sensor checkFSCB CN23-3 (ON)FS-535 11 to 12-L
4PS51 I/O check, sensor checkFSCB CN23-6 (ON)FS-535 12-L
5PS52 I/O check, sensor checkFSCB CN23-9 (ON)FS-535 12-L
6PS53 I/O check, sensor checkFSCB CN23-12 (ON)FS-535 12-L
7M13 operation checkFSCB CN15-3 to 8FS-535 8-D
8Replace M13 (Part# 56AA80112)
9FSCB ICP18 conduction check
10Replace FSCB (Part# A2Y1H10002)

K3.6.10 (Link to the Field Service Manual)

Table of Contents