C1109 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When FS-533 is installed
Contents
Trouble type | C1109: Stapler motor drive malfunction (When FS-533 is installed) |
Rank | B |
Trouble detection condition | The stapler home sensor (PS110) is not turned ON (blocked) even after the set period of time has elapsed after the stapler motor is energized. |
Trouble isolation | Staple |
Relevant electrical parts | -Stapler unit -Stapler home sensor (PS110) -Stapler relay board (STRYB) -FS control board (FSCB) |
Procedure
- Check the connector between the stapler unit-STRYB CN122, CN123 for proper connection and correct as necessary.
- Check the connector of the stapler unit for proper drive coupling and correct as necessary.
- Check the connector between PS110-FSCB CN110 for proper connection and correct as necessary.
- PS110 I/O check, sensor check
- Control signal: FSCB CN110
- Location of electrical component: FS-533 8-D to E
- Replace the stapler unit. (Part# A2YUPPK401)
- Replace STRYB. (Part# A2YUPPG700)
- Replace FSCB. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))
When FS-539 or FS-539SD is installed
Contents
Trouble type | C1109: Stapler motor drive malfunction (When FS-539 or FS-539SD is installed) |
Rank | B |
Trouble detection condition | -The stapler sensor is not turned OFF or ON even after the set period of time has elapsed after the stapler motor is energized. -The stapler center position sensor (PS24) is turned ON (blocked), when the stapler motor is running. |
Trouble isolation | Staple |
Relevant electrical parts | -Stapler unit -Stapler center position sensor (PS24) -FS control board (FSCB) |
Procedure
- Check the connector between the stapler unit-relay CN6-FSCB J11 for proper connection and correct as necessary.
- Check the connector of the stapler unit for proper drive coupling and correct as necessary.
- Check the connector between PS24-relay CN3-FSCB J11 for proper connection and correct as necessary.
- PS24 I/O check, sensor check
- Control signal: FSCB J11<B>-6 (ON)
- Location of electrical component: FS-539/FS-539SD 5-C
- Replace the stapler unit. (Part# A3EP560100)
- Replace FSCB. (Part# AAR4PP8201)
When FS-540 or FS-540SD is installed
Contents
Trouble type | C1109: Stapler motor drive malfunction (When FS-540 or FS-540SD is installed) |
Rank | B |
Trouble detection condition | -The stapler sensor is not turned OFF or ON even after the set period of time has elapsed after the stapler motor (M5) is energized. -The stapler center position sensor (PS20) is turned ON (blocked), when the stapler motor (M5) is running. |
Trouble isolation | Staple |
Relevant electrical parts | -Stapler unit -Stapler center position sensor (PS20) -FS control board (FSCB) |
Procedure
- Check the connector between the stapler unit-FSCB J17 for proper connection and correct as necessary.
- Check the connector of the stapler unit for proper drive coupling and correct as necessary.
- Check the connector between PS20-FSCB J16 for proper connection and correct as necessary.
- PS20 I/O check, sensor check
- Control signal: FSCB J16<A>-3
- Location of electrical component: FS-540/FS-540SD 14-K to L
- Replace the stapler unit. (Part# AAR5PPE200)
- Replace FSCB. (Part# AAR5PPD401)
L.3.8.10 (Link to the Field Service Manual)