C1112 (bizhub C364e/C284e/C224e)
Contents
Trouble type | Stapler motor’s malfunction | |
Trouble code | C1112 | |
Rank | B | |
Detection timing | <When FS-534+SD-511 is installed> • The stapler home sensor is not turned ON even after the set period of time has elapsed while the stapler motor is energized. • The stapler home sensor is not turned OFF even after the set period of time has elapsed after the stapler home sensor is turned ON. | |
Trouble isolation | • Staple • Half-Fold/Tri-Fold Center Stapling | |
Relevant electrical parts | • Staple unit • SD drive board (SDDB) • FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between the staple unit-SDDB J4 for proper connection and correct as necessary. | – | – |
2 | Check the connector of the staple unit for proper drive coupling and correct as necessary. | – | – |
3 | Replace the staple unit (Part# A3ER929300) | – | – |
4 | Replace SDDB (Part# A3ERPP6J03) | – | – |
5 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.20. C1112)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.8 (Link to the Field Service Manual)