C1113 (bizhub 364e/284e/224e)
Contents
Trouble type | Center-staple lead edge stopper motor malfunction | |
Trouble code | C1113 | |
Rank | B | |
Detection timing | <When FS-534+SD-511 is installed> The stopper home sensor (PS6) is not blocked or unblocked even after the set period of time has elapsed after the stopper drive motor (M4) is turned ON. | |
Trouble isolation | • Staple • Half-Fold/Tri-Fold Center Stapling | |
Relevant electrical parts | • Stopper drive motor (M4) • Stopper home sensor (PS6) • SD drive board (SDDB) • FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M4-SDDB J10 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M4 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS6-SDDB J10 for proper connection, and correct as necessary. | – | – |
4 | PS6 I/O check, sensor check | SDDB J10-5 (ON) | SD-511 2-G |
5 | M4 operation check | SDDB J10-6 to 9 | SD-511 1 to 2-F to G |
6 | Replace M4 (Part# A3ERPP3N00) | – | – |
7 | Replace SDDB (Part# A3ERPP6J03 ) | – | – |
8 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.8 SD-511)
- Link to the layout drawings for related parts by each trouble code (S.21. C1113)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
(Link to the Field Service Manual) K.3.6.9