How Can We Help?

C1113 (bizhub 554e/454e)

You are here:

Contents

Trouble typeCenter-staple lead edge stopper motor malfunction
Trouble codeC1113
RankB
Detection timing<When FS-534+SD-511 is installed> or <When FS-535+SD-512 is installed>
The stopper home sensor (PS6) is not blocked or unblocked even after the set period of time has elapsed after the stopper drive motor (M4) is turned ON.
Trouble isolationStapleHalf-Fold/Tri-Fold Center Stapling
Relevant electrical parts<When FS-534+SD-511 is installed> or <When FS-535+SD-512 is installed>
• Stopper drive motor (M4)
• Stopper home sensor (PS6)
• SD drive board (SDDB)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534+SD-511 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M4-SDDB J10 for proper connection and correct as necessary.
2Check the connector of M4 for proper drive coupling, and correct as necessary.
3Check the connector between PS6-SDDB J10 for proper connection, and correct as necessary.
4PS6 I/O check, sensor checkSDDB J10-5 (ON)SD-511 2-G
5M4 operation checkSDDB J10-6 to 9SD-511 1 to 2-F to G
6Replace M4 (Part# A3ERPP3N00)
7Replace SDDB (Part# A3EPPPBE01)
8Replace FSCB (Part# A3EPPPBE01)

When FS-535+SD-512 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M4-SDDB J10 for proper connection, and correct as necessary.
2Check the connector of M4 for proper drive coupling, and correct as necessary.
3Check the connector between PS6-SDDB J10 for proper connection, and correct as necessary.
4PS6 I/O check, sensor checkSDDB J10-5 (ON)SD-512 1-G
5M4 operation checkSDDB J10-6 to 9SD-512 1-F to G
6Replace M4 (Part# A3EPPP5600)
7Replace SDDB (Part# A2Y1H10002)
8Replace FSCB (Part# A2Y1H10002)