Trouble typeC1113: Stopper drive motor malfunction
RankB
Trouble detection condition<When FS-536SD or FS-537SD is installed>
The stopper home sensor (PS6) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the stopper drive motor (M4) is turned ON.
Trouble isolation• Staple
• Center Stapling/Half-Fold/Tri-Fold
Relevant electrical parts<When FS-536SD or FS-537SD is installed>
• Stopper drive motor (M4)
• Stopper home sensor (PS6)
• SD control board (SDCB)
• FS control board (FSCB)

 Procedure

  1. Check the connector between M4-SDCB J10 for proper connection and correct as necessary.
  2. Check the connector of M4 for proper drive coupling and correct as necessary.
  3. Check the connector between PS6-SDCB J10 for proper connection and correct as necessary.
  4. PS6 I/O check, sensor check
    • Control signal: SDCB J10-5 (ON)
    • Location of electrical component: FS-536/FS-536SD 2-P, FS-537/FS-537SD 2-P
  5. M4 operation check
    • Control signal: SDCB J10-6 to 9
    • Location of electrical component: FS-536/FS-536SD 2-P, FS-537/FS-537SD 1-P
  6. Replace M4. (FS-536SD Part# A3EPPP5600/ FS-537SD Part# A87HPPBW00)
  7. Replace SDCB. (FS-536SD Part# A3EP560100 / FS-537SD Part# A3ER929300 )
  8. Replace FSCB. (FS-536SD Part# A87GPP0V00 / FS-537SD Part# A87HPP9M01)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.8.12 (Link to the Field Service Manual)