C1114 (bizhub 754e/654e)

You are here:

Contents

Trouble typeAlignment motor’s malfunction
Trouble codeC1114
RankB
Detection timing<When FS-534+SD-511 is installed><When FS-535+SD-512 is installed>
The alignment home sensor (PS4) is not blocked or unblocked even after the set period of time has elapsed after the alignment motor (M3) is turned ON.
Trouble isolation• Half-Fold/Tri-Fold Center Stapling
Relevant electrical parts<When FS-534+SD-511 is installed><When FS-535+SD-512 is installed
• Alignment motor (M3)
• Alignment home sensor (PS4)
• SD drive board (SDDB)
• FS control board (FSCB)


 (2)ProcedureWhen FS-534+SD-511 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M3-relay CN10-SDDB J7 for proper connection, and correct as necessary.
2Check the connector of M3 for proper drive coupling, and correct as necessary.
3Check the connector between PS4-relay CN10-SDDB J7 for proper connection, and correct as necessary.
4PS4 I/O check, sensor checkSDDB J7-6 (ON)SD-511 6-F
5M3 operation checkSDDB J7-7 to 10SD-511 5-F to G
6Replace M3 (Part# A3EPPP5600 )
7Replace SDDB (Part# A3ERPP6J03 )
8Replace FSCB (Part# A3EPPPBE01 )

When FS-535+SD-512 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M3-relay CN10-SDDB J7 for proper connection, and correct as necessary.
2Check the connector of M3 for proper drive coupling, and correct as necessary.
3Check the connector between PS4-relay CN10-SDDB J7 for proper connection, and correct as necessary.
4PS4 I/O check, sensor checkSDDB J7-6 (ON)SD-512 5-G
5M3 operation checkSDDB J7-7 to 10SD-512 5-F to G
6Replace M3 (Part# A2Y1M10000 )
7Replace SDDB (Part# A3ERPP6J03 )
8Replace FSCB (Part# A2Y1H10002 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) C1114