C1114 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When FS-539SD is installed
Contents
Trouble type | C1114: Alignment motor drive malfunction (When FS-539SD is installed) |
Rank | B |
Trouble detection condition | The alignment home sensor (PS104) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the alignment motor (M103) is energized. |
Trouble isolation | Center Stapling/Half-Fold/Tri-Fold |
Relevant electrical parts | – Alignment motor (M103) – Alignment home sensor (PS104) – SD control board (SDCB) – FS control board (FSCB) |
Procedure
- Check the connector between M103-relay CN26-SDCB J7 for proper connection and correct as necessary.
- Check the connector of M103 for proper drive coupling and correct as necessary.
- Check the connector between PS104-relay CN26-SDCB J7 for proper connection and correct as necessary.
- PS104 I/O check, sensor check
- Control signal: SDCB J7-6 (ON)
- Location of electrical component: FS-539/FS-539SD 6-P
- M103 operation check
- Control signal: SDCB J7-7 to 10
- Location of electrical component: FS-539/FS-539SD 6-P
- Replace M103.
- Replace SDCB.
- Replace FSCB.
When FS-540SD is installed
Contents
Trouble type | C1114: Alignment motor drive malfunction (When FS-540SD is installed) |
Rank | B |
Trouble detection condition | The alignment home sensor (PS104) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the alignment motor (M103) is energized. |
Trouble isolation | Center Stapling/Half-Fold/Tri-Fold |
Relevant electrical parts | – Alignment motor (M103) – Alignment home sensor (PS104) – SD control board (SDCB) – FS control board (FSCB) |
Procedure
- Check the connector between M103-relay CN29-SDCB J7 for proper connection and correct as necessary.
- Check the connector of M103 for proper drive coupling and correct as necessary.
- Check the connector between PS104-relay CN29-SDCB J7 for proper connection and correct as necessary.
- PS104 I/O check, sensor check
- Control signal: SDCB J7-6 (ON)
- Location of electrical component: FS-540/FS-540SD 6-P
- M103 operation check
- Control signal: SDCB J7-7 to 10
- Location of electrical component: FS-540/FS-540SD 5-P
- Replace M103.
- Replace SDCB.