C1114 (bizhub C364e/C284e/C224e)
Contents
Trouble type | Center-staple front adjust drive motor malfunction | |
Trouble code | C1114 | |
Rank | B | |
Detection timing | <When FS-534+SD-511 is installed> The alignment home sensor (PS4) is not blocked or unblocked even after the set period of time has elapsed after the alignment motor (M3) is turned ON. | |
Trouble isolation | Half-Fold/Tri-Fold Center Stapling | |
Relevant electrical parts | • Alignment motor (M3) • Alignment home sensor (PS4) • SD drive board (SDDB) • FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M3-relay CN10-SDDB J7 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M3 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS4-relay CN10-SDDB J7 for proper connection, and correct as necessary. | – | – |
4 | PS4 I/O check, sensor check | SDDB J7-6 (ON) | SD-511 6-F |
5 | M3 operation check | SDDB J7-7 to 10 | SD-511 5-F to G |
6 | Replace M3 (Part# A3ERPP3N00) | – | – |
7 | Replace SDDB (Part# A3ERPP6J03) | – | – |
8 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.8 SD-511)
- Link to the layout drawings for related parts by each trouble code (S.22. C1114)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.10 (Link to the Field Service Manual)