C1114 (bizhub C754/C654)

You are here:

Contents

Trouble typeAlignment motor malfunction
Trouble codeC1114
RankB
Detection timing<When FS-534+SD-511 is installed><When FS-535+SD-512 is installed>
The alignment home sensor (PS4) is not blocked or unblocked even after the set period of time has elapsed after the alignment motor (M3) is turned ON.
Trouble isolationHalf-Fold/Tri-Fold Center Stapling
Relevant electrical parts<When FS-534+SD-511 is installed><When FS-535+SD-512 is installed>
Alignment motor (M3)Alignment home sensor (PS4)SD drive board (SDDB)FS control board (FSCB)

(2)ProcedureWhen FS-534+SD-511 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M3-relay CN10-SDDB J7 for proper connection, and correct as necessary.
2Check the connector of M3 for proper drive coupling, and correct as necessary.
3Check the connector between PS4-relay CN10-SDDB J7 for proper connection, and correct as necessary.
4PS4 I/O check, sensor checkSDDB J7-6 (ON)SD-511 6-F
5M3 operation checkSDDB J7 7 to 10SD-511 5-F to G
6Replace M3 (Part# A3ERPP3N00)
7Replace SDDB (Part# A3ERPP6J03)
8Replace FSCB (Part# A3EPPPBE01)

When FS-535+SD-512 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M3-relay CN10-SDDB J7 for proper connection, and correct as necessary.
2Check the connector of M3 for proper drive coupling, and correct as necessary.
3Check the connector between PS4-relay CN10-SDDB J7 for proper connection, and correct as necessary.
4PS4 I/O check, sensor checkSDDB J7-6 (ON)SD-512 5-G
5M3 operation checkSDDB J7-7 to 10SD-512 5-F to G
6Replace M3 (Part# A3EPPP5600)
7Replace SDDB (Part# A3ERPP6J03)
8Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.14 (Link to the Field Service Manual)