How Can We Help?

C1124 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC1124: Tray lift motor /Lw’s drive malfunction
RankB
Trouble detection condition<FS-537+PI-507, FS-537SD+PI-507 is installed>The tray upper limit sensor /Lw (PS209) or tray lower limit sensor /Lw (PS210) is not turned ON (blocked) after the set period of time has elapsed after the tray lift motor /Lw (M202) is turned ON.
Trouble isolationPost inserter
Relevant electrical parts•Tray lift motor /Lw (M202)
• Tray upper limit sensor /Lw (PS209)
• Tray lower limit sensor /Lw (PS210)
• PI drive board (PIDB)
• FS control board (FSCB)

 Procedure

  1. Check the connector between M202-relay CN206-PIDB CN56 for proper connection and correct as necessary.
  2. Check the connector of M202 for proper drive coupling and correct as necessary.
  3. Check the connector between PS209-relay CN237-PIDB CN53 for proper connection and correct as necessary.
  4. Check the connector between PS210-relay CN236-PIDB CN53 for proper connection and correct as necessary.
  5. PS209 I/O check, sensor check
    • Control signal: PIDB CN53<A>-8 (ON)
    • Location of electrical component: PI-507 10-C
  6. PS210 I/O check, sensor check
    • Control signal: PIDB CN53<A>-11 (ON)
    • Location of electrical component: PI-507 11-C
  7. M202 operation check
    • Control signal: PIDB CN56-5 to 6
    • Location of electrical component: PI-507 9-C
  8. Replace M202. (Part# A10YA6560)
  9. Replace PIDB. (Part# A8C6H00101)
  10. Replace FSCB. (Part# A87HPP9M01)

NOTICE

  • Link to the wiring diagram (PI-507)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.15 (Link to the Field Service Manual)

Table of Contents