C1124 (bizhub C754e/C654e)
Contents
Trouble type | Sheet feeder up/down drive failure (lower) | |
Trouble code | C1124 | |
Rank | B | |
Detection timing | <When FS-535+PI-505 is installed> The tray upper limit sensor /Lw (PS209) or tray lower limit sensor /Lw (PS210) are not turned ON even after the set period of time has elapsed after the tray lift motor /Lw (M202) is energized. | |
Trouble isolation | Post Inserter | |
Relevant electrical parts | • Tray lift motor /Lw (M202) • Tray upper limit sensor /Lw (PS209) • Tray lower limit sensor /Lw (PS210) • PI drive board (PIDB) • FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M202-relay CN206-PIDB CN56 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M202 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS209-relay CN237-PIDB CN53<A> for proper connection, and correct as necessary. | – | – |
4 | Check the connector between PS210-relay CN236-PIDB CN53<A> for proper connection, and correct as necessary. | – | – |
5 | PS209 I/O check, sensor check | PIDB CN53<A>-8 (ON) | PI-505 8-C to D |
6 | PS210 I/O check, sensor check | PIDB CN53<A>-11 (ON) | PI-505 9-C to D |
7 | M202 operation check | PIDB CN56-5 to 6 | PI-505 7-C to D |
8 | Replace M202 (Part# A10YA6560) | – | – |
9 | PIDB ICP2 conduction check | – | – |
10 | Replace PIDB (Part# A10AH01001) | – | – |
11 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.2.10 Post inserter PI-505)
- Link to the layout drawings for related parts by each trouble code (S.25. C1124)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.6.16 (Link to the Field Service Manual)