C1124 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC1124: Tray lift motor /Lw drive malfunction
RankB
Trouble detection condition<FS-537+PI-507, FS-537SD+PI-507 is installed>
The tray upper limit sensor /Lw (PS209) or tray lower limit sensor /Lw (PS210) is not turned ON (blocked) after the set period of time has elapsed after the tray lift motor /Lw (M202) is turned ON.
Trouble isolationPost inserter
Relevant electrical parts-Tray lift motor /Lw (M202)
-Tray upper limit sensor /Lw (PS209)
-Tray lower limit sensor /Lw (PS210)
-PI drive board (PIDB)
-FS control board (FSCB)

 Procedure

  1. Check the connector between M202-relay CN206-PIDB CN56 for proper connection and correct as necessary.
  2. Check the connector of M202 for proper drive coupling and correct as necessary.
  3. Check the connector between PS209-relay CN237-PIDB CN53 for proper connection and correct as necessary.
  4. Check the connector between PS210-relay CN236-PIDB CN53 for proper connection and correct as necessary.
  5. PS209 I/O check, sensor check
    • Control signal: PIDB CN53<A>-8 (ON)
    • Location of electrical component: PI-507 10-C
  6. PS210 I/O check, sensor check
    • Control signal: PIDB CN53<A>-11 (ON)
    • Location of electrical component: PI-507 11-C
  7. M202 operation check
    • Control signal: PIDB CN56-5 to 6
    • Location of electrical component: PI-507 9-C
  8. Replace M202. (Part# A10YA6560)
  9. Replace PIDB. (Part# A8C6H00101)
  10. Replace FSCB. (Part# A87HPP9M01)

L.3.8.15 (Link to the Field Service Manual)