C1125 (bizhub 558/458)

You are here:

Contents

Trouble typeC1125: Tray lift motor /Up’s drive malfunction
RankB
Trouble detection condition<FS-537+PI-507, FS-537SD+PI-507 is installed>
The tray upper limit sensor /Up (PS204) or tray lower limit sensor /Up (PS205) is not turned ON (blocked) after the set period of time has elapsed after the tray lift motor /Up (M201) is turned ON.
Trouble isolationPost inserter
Relevant electrical parts• Tray lift motor /Up (M201)
• Tray upper limit sensor /Up (PS204)
• Tray lower limit sensor /Up (PS205)
• PI drive board (PIDB)
• FS control board (FSCB)

 Procedure

  1. Check the connector between M201-relay CN203-PIDB CN54 for proper connection and correct as necessary.
  2. Check the connector of M201 for proper drive coupling and correct as necessary.
  3. Check the connector between PS204-relay CN235-PIDB CN55 for proper connection and correct as necessary.
  4. Check the connector between PS205-relay CN235-PIDB CN55 for proper connection and correct as necessary.
  5. PS204 I/O check, sensor check
    • Control signal: PIDB CN55-8 (ON)
    • Location of electrical component: PI-507 8-C
  6. PS205 I/O check, sensor check
    • Control signal: PIDB CN55-7 (ON)
    • Location of electrical component: PI-507 8-C
  7. M201 operation check
    • Control signal: PIDB CN54-7 to 8
    • Location of electrical component: PI-507 6 to 7-C
  8. Replace M201. (Part# ?)
  9. Replace PIDB. (Part# A8C6H00101)
  10. Replace FSCB. (Part# A87HPP9M01)

NOTICE

  • Link to the wiring diagram (PI-507)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.9.16 (Link to the Field Service Manual)