How Can We Help?

C1125 (bizhub 750i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC1125: Tray lift motor/Up drive malfunction (When FS-540+PI-507 or FS-540SD+PI-507 is installed)
RankB
Trouble detection conditionThe tray upper limit sensor/Up (PS204) or tray lower limit sensor/Up (PS205) is not turned ON (blocked) after the set period of time has elapsed after the tray lift motor/Up (M201) is energized.
Trouble isolationPost inserter
Relevant electrical parts-Tray lift motor/Up (M201)
-Tray upper limit sensor/Up (PS204)
-Tray lower limit sensor/Up (PS205)
-PI drive board (PIDB)
-FS control board (FSCB)

Procedure

  1. Check the connector between M201-relay CN203-PIDB CN54 for proper connection and correct as necessary.
  2. Check the connector of M201 for proper drive coupling and correct as necessary.
  3. Check the connector between PS204-relay CN235-PIDB CN55 for proper connection and correct as necessary.
  4. Check the connector between PS205-relay CN235-PIDB CN55 for proper connection and correct as necessary.
  5. PS204 I/O check, sensor check
    • Control signal: PIDB CN55-8 (ON)
    • Location of electrical component: PI-507 8-C
  6. PS205 I/O check, sensor check
    • Control signal: PIDB CN55-7 (ON)
    • Location of electrical component: PI-507 8-C
  7. M201 operation check
    • Control signal: PIDB CN54-7 to 8
    • Location of electrical component: PI-507 6 to 7-C
  8. Replace M201. (Part# A3EWPP3201)
  9. Replace PIDB. (Part# A8C6H00101)
  10. Replace FSCB. (Part# AAR5PPD401)

(Link to the Field Service Manual)