How Can We Help?

C1125 (bizhub C554/C454)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeSheet feeder up/down drive failure (upper)
Trouble codeC1125
RankB
Detection timing<When FS-535+PI-505 is installed>
The tray lower limit sensor /Up (PS205) or tray upper limit sensor /Up (PS204) are not turned ON even after the set period of time has elapsed after the tray lift motor /Up (M201) is energized.
Trouble isolationPost Inserter
Relevant electrical parts-Tray lift motor /Up (M201)
-Tray upper limit sensor /Up (PS204)
-Tray lower limit sensor /Up (PS205)
-PI drive board (PIDB)
-FS control board (FSCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M201-relay CN203-PIDB CN54 for proper connection, and correct as necessary.
2Check the connector of M201 for proper drive coupling, and correct as necessary.
3Check the connector between PS204-relay CN235-PIDB CN55 for proper connection, and correct as necessary.
4Check the connector between PS205-relay CN235-PIDB CN55 for proper connection, and correct as necessary.
5PS204 I/O check, sensor checkPIDB CN55-8 (ON)PI-505 5-C to D
6PS205 I/O check, sensor checkPIDB CN55-7 (ON)PI-505 6-C to D
7M201 operation checkPIDB CN54-7 to 8PI-505 4-C to D
8Replace M201 (Part# A10YA6560)
9PIDB ICP2 conduction check
10Replace PIDB (Part# A10AH01001)
11Replace FSCB (Part# A2Y1H10002)
  • Link to the wiring diagram (N.3.13 PI-505)
  • Link to the layout drawings for related parts by each trouble code (S.30. C1125)

K3.6.17 (Link to the Field Service Manual)

Table of Contents