How Can We Help?

C1125 (bizhub C754/C654)

You are here:

Contents

Trouble typeSheet feeder up/down drive failure (upper)
Trouble codeC1125
RankB
Detection timing<When FS-535+PI-505 is installed>
The tray lower limit sensor /Up (PS205) or tray upper limit sensor /Up (PS204) are not turned ON even after the set period of time has elapsed after the tray lift motor /Up (M201) is energized.
Trouble isolationPost Inserter
Relevant electrical parts-Tray lift motor /Up (M201)
-Tray upper limit sensor /Up (PS204)
-Tray lower limit sensor /Up (PS205)
-PI drive board (PIDB)
-FS control board (FSCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M201-relay CN203-PIDB CN54 for proper connection, and correct as necessary.
2Check the connector of M201 for proper drive coupling, and correct as necessary.
3Check the connector between PS204-relay CN235-PIDB CN55 for proper connection, and correct as necessary.
4Check the connector between PS205-relay CN235-PIDB CN55 for proper connection, and correct as necessary.
5PS204 I/O check, sensor checkPIDB CN55-8 (ON)PI-505 5-C to D
6PS205 I/O check, sensor checkPIDB CN55-7 (ON)PI-505 6-C to D
7M201 operation checkPIDB CN54-7 to 8PI-505 4-C to D
8Replace M201 (Part# A10YA6560)
9PIDB ICP2 conduction check
10Replace PIDB (Part# A10AH01001)
11Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.17 (Link to the Field Service Manual)

Table of Contents