C1131 (bizhub 558/458)
Contents
Trouble type | C1131: Folding guide motor drive malfunction | |
Rank | B | |
Trouble detection condition | <When FS-537+ZU-609 or FS-537SD+ZU-609 is installed> The guide home sensor (PS500) is not turned ON (blocked) even after the set period of time has elapsed after the folding guide motor (M501) is turned ON. | |
Trouble isolation | Z fold | |
Relevant electrical parts | • Folding guide motor (M501) • Guide home sensor (PS500) • ZU drive board (ZUDB) |
Procedure
- Check the connector between M501-ZUDB CN6 for proper connection and correct as necessary.
- Check the connector of M501 for proper drive coupling and correct as necessary.
- Check the connector between PS500-ZUDB CN5 for proper connection and correct as necessary.
- PS500 I/O check, sensor check
- Control signal: ZUDB CN5-3 (ON)
- Location of electrical component: ZU-609 3-B
- M501 operation check
- Control signal: ZUDB CN6-9 to 12
- Location of electrical component: ZU-609 2-B
- Replace M501. (Part# A63GR70000)
- Replace ZUDB. (Part# A63GH00100)
NOTICE
- Link to the wiring diagram (ZU-609)