C1132 (bizhub 754e/654e)
Contents
Trouble type | Punch drive motor’s malfunction | |
Trouble code | C1132 | |
Rank | B | |
Detection timing | <When FS-534+PK-520 is installed> The punch home sensor (PS1) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M1) is energized. | |
<When FS-535+PK-521 is installed> The PK punch home sensor/2 (PS301) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M301) is energized. | ||
Trouble isolation | – | |
Relevant electrical parts | <When FS-534+PK-520 is installed> • Punch drive motor (M1) • Punch home sensor (PS1) • FS control board (FSCB) | |
<When FS-535+PK-521 is installed> • Punch drive motor (M301) • PK punch home sensor/2 (PS301) • Punch control board (PKCB) • FS control board (FSCB) |
(2)ProcedureWhen FS-534+PK-520 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M1-relay CN351-FSCB J7 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M1 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS1-FSCB J7 for proper connection, and correct as necessary. | – | – |
4 | PS1 I/O check, sensor check | FSCB J7-5 (ON) | FS-534 (PK-520) 7-K |
5 | M1 operation check | FSCB J7-7 to 8 | FS-534 (PK-520) 7-K |
6 | Replace M1 (Punch unit 2/3 hole# A4JUF93100 )( Punch unit 2/4 hole Part# A4JUF93200 ) | – | – |
7 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.2.4 Finisher FS-534)
- Link to the layout drawings for related parts by each trouble code (S.30.1 PK-520)
When FS-535+PK-521 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M301-relay CN351-PKCB CN35 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M301 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS301-PKCB CN36 for proper connection, and correct as necessary. | – | – |
4 | PS301 I/O check, sensor check | PKCB CN36-5 (ON) | PK-521 3-C |
5 | M301 operation check | PKCB CN35-1 to 3 | PK-521 2-C |
6 | Replace M301 ( Punch unit 2/3 hole Part# A4JUR70500 )( Punch unit 2/4 hole Part# A4JUR70600 ) | – | – |
7 | Replace PKCB (Part# A2YRH10103 ) | – | – |
8 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.2.8 Punch kit PK-521)
- Link to the layout drawings for related parts by each trouble code (S.30.2 PK-521)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
(Link to the Field Service Manual) K.3.6.21