Trouble typeC1132: Punch drive motor drive malfunction
RankB
Trouble detection condition<When FS-536+PK-520 or FS-536SD+PK-520 is installed>
The punch home sensor (PS1) is not turned ON (unblocked) or OFF (blocked) even after the set period of time has elapsed while the punch drive motor (M1) is energized.
<When FS-537+PK-523 or FS-537SD+PK-523 is installed>
The PK punch home sensor/2 (PS301) is not turned ON (unblocked) or OFF (blocked) even after the set period of time has elapsed while the punch drive motor (M301) is energized.
Trouble isolation
Relevant electrical parts<When FS-536+PK-520 or FS-536SD+PK-520 is installed>
-Punch drive motor (M1)
-Punch home sensor (PS1)
-FS control board (FSCB)
<When FS-537+PK-523 or FS-537SD+PK-523 is installed>
-Punch drive motor (M301)
-PK punch home sensor/2 (PS301)
-Punch control board (PKCB)
-FS control board (FSCB)

 Procedure

 When FS-536+PK-520 or FS-536SD+PK-520 is installed

  1. Check the connector between M1-relay CN351-FSCB J7 for proper connection and correct as necessary.
  2. Check the connector of M1 for proper drive coupling and correct as necessary.
  3. Check the connector between PS1-FSCB J7 for proper connection and correct as necessary.
  4. PS1 I/O check, sensor check
    • Control signal: FSCB J7-5 (ON)
    • Location of electrical component: FS-536/FS-536SD 13-K
  5. M1 operation check
    • Control signal: FSCB J7-7 to 8
    • Location of electrical component: FS-536/FS-536SD 13-K
  6. Replace M1. (Part# A3ERPP2F00)
  7. Replace FSCB. (Part# A87GPP0V00)

 When FS-537+PK-523 or FS-537SD+PK-523 is installed

  1. Check the connector between M301-relay CN351-PKCB CN35 for proper connection and correct as necessary.
  2. Check the connector of M301 for proper drive coupling and correct as necessary.
  3. Check the connector between PS301-PKCB CN36 for proper connection and correct as necessary.
  4. PS301 I/O check, sensor check
    • Control signal: PKCB CN36-5 (ON)
    • Location of electrical component: PK-523 3-C
  5. M301 operation check
    • Control signal: PKCB CN35-1 to 3
    • Location of electrical component: PK-523 2-C
  6. Replace M301. (Part# A4JUF92000 Punch Unit /1 / Part# A4JUF92100 Punch Unit /2 / Part# A4JUF92200 Punch Unit /3)
  7. Replace PKCB. (Part# A99KH00103)
  8. Replace FSCB. (Part# A87HPP9M01)