How Can We Help?

C1135 (bizhub 554e/454e)

You are here:

Contents

Trouble typePunch motor’s drive malfunction
Trouble codeC1135
RankB
Detection timing<When FS-535+ZU-606 is installed>
The punch motor (M604) is not turned OFF even after the set period of time has elapsed after it is turned ON.
Trouble isolation
Relevant electrical parts• Punch motor (M604)
• ZU control board (ZUCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M604-relay CN644-relay CN638-ZUCB CN11 for proper connection, and correct as necessary.
2Check the connector of M604 for proper drive coupling, and correct as necessary.
3M604 operation checkZUCB CN11-2 (DRV)ZU-606 7-C
4Replace M604 (Part# A111A9160)
5ZUCB ICP10 conduction check
6Replace ZUCB (Part# A109H01002)
  • Link to the wiring diagram (N.3.14 ZU-606)
  • Link to the layout drawings for related parts by each trouble code (S.37. C1135)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.24 (Link to the Field Service Manual)

Table of Contents