C1135 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Punch motor drive malfunction | |
Trouble code | C1135 | |
Rank | B | |
Detection timing | <When FS-535+ZU-606 is installed> The punch motor (M604) is not turned OFF even after the set period of time has elapsed after it is turned ON. | |
Trouble isolation | – | |
Relevant electrical parts | -Punch motor (M604) -ZU control board (ZUCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M604-relay CN644-relay CN638-ZUCB CN11 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M604 for proper drive coupling, and correct as necessary. | – | – |
3 | M604 operation check | ZUCB CN11-2 (DRV) | ZU-606 7-C |
4 | Replace M604 (Part# A111A9160) | – | – |
5 | ZUCB ICP10 conduction check | – | – |
6 | Replace ZUCB (Part# A109H01002) | – | – |
- Link to the wiring diagram (N.3.14 ZU-606)
- Link to the layout drawings for related parts by each trouble code (S.37. C1135)