How Can We Help?

C1136 (bizhub 754e/654e)

You are here:

Contents

Trouble typePunch switchover motor’s drive malfunction
Trouble codeC1136
RankB
Detection timing<When FS-535+ZU-606 is installed>
The punch switchover switch (MS601) is not turned OFF from the ON position, or not turned ON from the OFF position, even after the set period of time has elapsed after the punch switchover motor (M608) is turned ON.
Trouble isolationZ fold
Relevant electrical parts• Punch switchover motor (M608)
• Punch switchover switch (MS601)
• ZU control board (ZUCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M608-relay CN633-relay CN638-ZUCB CN11 for proper connection, and correct as necessary.
2Check the connector of M608 for proper drive coupling, and correct as necessary.
3Check the connector between MS601-relay CN633-relay CN638-ZUCB CN11 for proper connection, and correct as necessary.
4MS601 I/O check, sensor checkZUCB CN11-9ZU-606 8-C
5M608 operation checkZUCB CN11-8 (DRV)ZU-606 7 to 8-C
6Replace M608 (Part# – A109A9130)
7ZUCB ICP9 conduction check
8Replace ZUCB (Part# A109H01002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.25 (Link to the Field Service Manual)

Table of Contents