How Can We Help?

C1140 (bizhub 360i/300i)

You are here:

When FS-533 is installed

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC1140: Alignment motor/Rr drive malfunction (When FS-533 is installed)
RankB
Trouble detection condition-The alignment plate home sensor/Rr (PS109) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.

-The alignment plate home sensor/Rr (PS109) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor/Rr (M106) is energized when the plate returned to the home position.
Trouble isolation
Relevant electrical parts-Alignment motor/Rr (M106)
-Alignment plate home sensor/Rr (PS109)
-FS control board (FSCB)

Procedure

  1. Check the connector between M106-FSCB CN102 for proper connection and correct as necessary.
  2. Check the connector of M106 for proper drive coupling and correct as necessary.
  3. Check the connector between PS109-FSCB CN102 for proper connection and correct as necessary.
  4. PS109 I/O check, sensor check
    • Control signal: FSCB CN102
    • Location of electrical component: FS-533 7-J
  5. M106 operation check
    • Control signal: FSCB CN102
    • Location of electrical component: FS-533 8-J
  6. Replace M106. (Part# A2YUPPW600)
  7. FSCB CP105 conduction check
  8. Replace FSCB. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))

 When FS-539 or FS-539SD is installed

Contents

Trouble typeC1140: Alignment motor/Rr drive malfunction (When FS-539 or FS-539SD is installed)
RankB
Trouble detection condition-The alignment plate home sensor/Rr (PS13) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.

-The alignment plate home sensor/Rr (PS13) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor/Rr (M8) is energized when the plate returned to the home position.

-The plate does not reach the specified position within the set period of time.
Trouble isolation
Relevant electrical parts-Alignment motor/Rr (M8)
-Alignment plate home sensor/Rr (PS13)
-FS control board (FSCB)

Procedure

  1. Check the connector between M8-relay CN19-FSCB J12 for proper connection and correct as necessary.
  2. Check the connector of M8 for proper drive coupling and correct as necessary.
  3. Check the connector between PS13-FSCB J9 for proper connection and correct as necessary.
  4. PS13 I/O check, sensor check
    • Control signal: FSCB J9<B>-12 (ON)
    • Location of electrical component: FS-539/FS-539SD 10-C
  5. M8 operation check
    • Control signal: FSCB J12-13 to 16
    • Location of electrical component: FS-539/FS-539SD 7-C
  6. Replace M8. (Part# A3EPPP5500)
  7. Replace FSCB. (Part# AAR4PP8201)

(Link to the Field Service Manual)

Table of Contents