C1140 (bizhub 360i/300i)
When FS-533 is installed
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C1140: Alignment motor/Rr drive malfunction (When FS-533 is installed) |
Rank | B |
Trouble detection condition | -The alignment plate home sensor/Rr (PS109) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. -The alignment plate home sensor/Rr (PS109) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor/Rr (M106) is energized when the plate returned to the home position. |
Trouble isolation | – |
Relevant electrical parts | -Alignment motor/Rr (M106) -Alignment plate home sensor/Rr (PS109) -FS control board (FSCB) |
Procedure
- Check the connector between M106-FSCB CN102 for proper connection and correct as necessary.
- Check the connector of M106 for proper drive coupling and correct as necessary.
- Check the connector between PS109-FSCB CN102 for proper connection and correct as necessary.
- PS109 I/O check, sensor check
- Control signal: FSCB CN102
- Location of electrical component: FS-533 7-J
- M106 operation check
- Control signal: FSCB CN102
- Location of electrical component: FS-533 8-J
- Replace M106. (Part# A2YUPPW600)
- FSCB CP105 conduction check
- Replace FSCB. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))
When FS-539 or FS-539SD is installed
Contents
Trouble type | C1140: Alignment motor/Rr drive malfunction (When FS-539 or FS-539SD is installed) |
Rank | B |
Trouble detection condition | -The alignment plate home sensor/Rr (PS13) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. -The alignment plate home sensor/Rr (PS13) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor/Rr (M8) is energized when the plate returned to the home position. -The plate does not reach the specified position within the set period of time. |
Trouble isolation | – |
Relevant electrical parts | -Alignment motor/Rr (M8) -Alignment plate home sensor/Rr (PS13) -FS control board (FSCB) |
Procedure
- Check the connector between M8-relay CN19-FSCB J12 for proper connection and correct as necessary.
- Check the connector of M8 for proper drive coupling and correct as necessary.
- Check the connector between PS13-FSCB J9 for proper connection and correct as necessary.
- PS13 I/O check, sensor check
- Control signal: FSCB J9<B>-12 (ON)
- Location of electrical component: FS-539/FS-539SD 10-C
- M8 operation check
- Control signal: FSCB J12-13 to 16
- Location of electrical component: FS-539/FS-539SD 7-C
- Replace M8. (Part# A3EPPP5500)
- Replace FSCB. (Part# AAR4PP8201)