Trouble typeC1140: Alignment motor/Rr drive malfunction
RankB
Trouble detection condition<When FS-533 is installed>
• The alignment plate home sensor/Rr (PS109) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position.
• The alignment plate home sensor/Rr (PS109) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor/Rr (M106) is energized when the plate returns to the home position.

<When FS-536 or FS-536SD is installed>
The alignment plate/Rr home sensor (PS13) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed while the alignment motor/Rr (M8) is energized.
Trouble isolation
Relevant electrical parts<When FS-533 is installed>
• Alignment motor/Rr (M106)
• Alignment plate home sensor/Rr (PS109)
• FS control board (FSCB)

<When FS-536 or FS-536SD is installed>
• Alignment motor/Rr (M8)
• Alignment plate/Rr home sensor (PS13)
• FS control board (FSCB)

Procedure

When FS-533 is installed

  1. Check the connector between M106-FSCB CN102 for proper connection and correct as necessary.
  2. Check the connector of M106 for proper drive coupling and correct as necessary.
  3. Check the connector between PS109-FSCB CN102 for proper connection and correct as necessary.
  4. PS109 I/O check, sensor check
    • Control signal: FSCB CN102
    • Location of electrical component: FS-533 7-J
  5. M106 operation check
    • Control signal: FSCB CN102
    • Location of electrical component: FS-533 8-J
  6. Replace M106. (Part# A2YUPPW600 )
  7. FSCB CP105 conduction check
  8. Replace FSCB. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))

When FS-536 or FS-536SD is installed

  1. Check the connector between M8-FSCB J12 for proper connection and correct as necessary.
  2. Check the connector of M8 for proper drive coupling and correct as necessary.
  3. Check the connector between PS13-FSCB J9 for proper connection and correct as necessary.
  4. PS13 I/O check, sensor check
    • Control signal: FSCB J9<B>-11 (ON)
    • Location of electrical component: FS-536/FS-536SD 10-C
  5. M8 operation check
    • Control signal: FSCB J12-13 to 16 (ON)
    • Location of electrical component: FS-536/FS-536SD 6-C
  6. Replace M8. (Part# A3EPPP5500 )
  7. Replace FSCB. (Part# A87GPP0V00 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.7.13 (Link to the Field Service Manual)