C1140 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Alignment plate motor/Rs malfunction | |
Trouble code | C1140 | |
Rank | B | |
Detection timing | <When FS-533 is installed> -The alignment plate home sensor/R (PS109) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position. -The alignment plate home sensor/R (PS109) is not blocked after the set period of time has elapsed when the plate returns to the home position. | |
<When FS-534 is installed> The alignment plate/R home sensor (PS13) is not blocked or unblocked even after the set period of time has elapsed while the alignment motor/Rr (M8) is energized. | ||
<When FS-535 is installed> The alignment plate motor home sensor/Rr (PS18) is not blocked even after the set period of time has elapsed while the alignment plate motor/Rr (M12) is energized. | ||
Trouble isolation | – | |
Relevant electrical parts | <When FS-533 is installed> -Alignment motor/R (M106) -Alignment plate home sensor/R (PS109) -FS control board (FSCB) | |
<When FS-534 is installed> -Alignment motor/Rear (M8) -Alignment plate/R home sensor (PS13) -FS control board (FSCB) | ||
<When FS-535 is installed> -Alignment plate motor/Rr (M12) -Alignment plate motor home sensor/Rr (PS18) -FS control board (FSCB) |
(2)Procedure When FS-533 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M106-FSCB CN102 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M106 for proper drive coupling and correct as necessary. | – | – |
3 | Check the connector between PS109-relay CN106-FSCB CN102 for proper connection and correct as necessary. | – | – |
4 | PS109 I/O check, sensor check | FSCB CN102 | FS-533 7-J |
5 | M106 operation check | FSCB CN102 | FS-533 8-J |
6 | Replace M106 (Part# A3EPPP5500) | – | – |
7 | FSCB CP105 conduction check | – | – |
8 | Replace FSCB (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2)) | – | – |
- Link to the wiring diagram (N.3.7 FS-533)
- Link to the layout drawings for related parts by each trouble code (S.39.1 FS-533)
When FS-534 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M8-FSCB J12 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M8 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS13-FSCB J9 for proper connection, and correct as necessary. | – | – |
4 | PS13 I/O check, sensor check | FSCB J9<B>-9 (ON) | FS-534 9-C |
5 | M8 operation check | FSCB J12-13 to 16 | FS-534 5 to 6-C to D |
6 | Replace M8 (Part#A2Y1R70200) | – | – |
7 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.3.8 FS-534)
- Link to the layout drawings for related parts by each trouble code (S.39.2 FS-534)
When FS-535 is installed
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M12-FSCB CN2 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M12 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS18-FSCB CN19 for proper connection, and correct as necessary. | – | – |
4 | PS18 I/O check, sensor check | FSCB CN20-3 (ON) | FS-535 11-D |
5 | M12 operation check | FSCB CN19-5 to 8 | FS-535 10-D |
6 | Replace M12 (Part#A2Y1R70200) | – | – |
7 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.3.10 FS-535)
- Link to the layout drawings for related parts by each trouble code (S.39.3 FS-535)