How Can We Help?

C1140 (bizhub C554/C454)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeAlignment plate motor/Rs malfunction
Trouble codeC1140
RankB
Detection timing<When FS-533 is installed>
-The alignment plate home sensor/R (PS109) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position.
-The alignment plate home sensor/R (PS109) is not blocked after the set period of time has elapsed when the plate returns to the home position.
<When FS-534 is installed>
The alignment plate/R home sensor (PS13) is not blocked or unblocked even after the set period of time has elapsed while the alignment motor/Rr (M8) is energized.
<When FS-535 is installed>
The alignment plate motor home sensor/Rr (PS18) is not blocked even after the set period of time has elapsed while the alignment plate motor/Rr (M12) is energized.
Trouble isolation
Relevant electrical parts<When FS-533 is installed>
-Alignment motor/R (M106)
-Alignment plate home sensor/R (PS109)
-FS control board (FSCB)
<When FS-534 is installed>
-Alignment motor/Rear (M8)
-Alignment plate/R home sensor (PS13)
-FS control board (FSCB)
<When FS-535 is installed>
-Alignment plate motor/Rr (M12)
-Alignment plate motor home sensor/Rr (PS18)
-FS control board (FSCB)

(2)Procedure When FS-533 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M106-FSCB CN102 for proper connection and correct as necessary.
2Check the connector of M106 for proper drive coupling and correct as necessary.
3Check the connector between PS109-relay CN106-FSCB CN102 for proper connection and correct as necessary.
4PS109 I/O check, sensor checkFSCB CN102FS-533 7-J
5M106 operation checkFSCB CN102FS-533 8-J
6Replace M106 (Part# A3EPPP5500)
7FSCB CP105 conduction check
8Replace FSCB (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))

When FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M8-FSCB J12 for proper connection, and correct as necessary.
2Check the connector of M8 for proper drive coupling, and correct as necessary.
3Check the connector between PS13-FSCB J9 for proper connection, and correct as necessary.
4PS13 I/O check, sensor checkFSCB J9<B>-9 (ON)FS-534 9-C
5M8 operation checkFSCB J12-13 to 16FS-534 5 to 6-C to D
6Replace M8 (Part#A2Y1R70200)
7Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M12-FSCB CN2 for proper connection, and correct as necessary.
2Check the connector of M12 for proper drive coupling, and correct as necessary.
3Check the connector between PS18-FSCB CN19 for proper connection, and correct as necessary.
4PS18 I/O check, sensor checkFSCB CN20-3 (ON)FS-535 11-D
5M12 operation checkFSCB CN19-5 to 8FS-535 10-D
6Replace M12 (Part#A2Y1R70200)
7Replace FSCB (Part# A2Y1H10002)

K3.6.26 (Link to the Field Service Manual)