C1140 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When FS-539 or FS-539SD is installed
Contents
Trouble type | C1140: Alignment motor/Rr drive malfunction (When FS-539 or FS-539SD is installed) |
Rank | B |
Trouble detection condition | -The alignment plate home sensor/Rr (PS13) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. -The alignment plate home sensor/Rr (PS13) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor/Rr (M8) is energized when the plate returned to the home position. -The plate does not reach the specified position within the set period of time. |
Trouble isolation | – |
Relevant electrical parts | -Alignment motor/Rr (M8) -Alignment plate home sensor/Rr (PS13) -FS control board (FSCB) |
Procedure
- Check the connector between M8-relay CN19-FSCB J12 for proper connection and correct as necessary.
- Check the connector of M8 for proper drive coupling and correct as necessary.
- Check the connector between PS13-FSCB J9 for proper connection and correct as necessary.
- PS13 I/O check, sensor check
- Control signal: FSCB J9<B>-12 (ON)
- Location of electrical component: FS-539/FS-539SD 10-C
- M8 operation check
- Control signal: FSCB J12-13 to 16
- Location of electrical component: FS-539/FS-539SD 7-C
- Replace M8. (Part# A3EPPP5500)
- Replace FSCB. (Part# AAR4PP8201)
When FS-540 or FS-540SD is installed
Contents
Trouble type | C1140: Alignment motor/Rr drive malfunction (When FS-540 or FS-540SD is installed) |
Rank | B |
Trouble detection condition | -The alignment plate home sensor/Rr (PS6) is not turned OFF (unblocked) after the set period of time has elapsed after the plate drive starts from the home position. -The alignment plate home sensor/Rr (PS6) is not turned ON (blocked) after the set period of time has elapsed while the alignment motor/Rr (M13) is energized when the plate returned to the home position. -The plate does not reach the specified position within the set period of time. |
Trouble isolation | – |
Relevant electrical parts | -Alignment motor/Rr (M13) -Alignment plate home sensor/Rr (PS6) -FS control board (FSCB) |
Procedure
- Check the connector between M13-relay CN3-FSCB J21 for proper connection and correct as necessary.
- Check the connector of M13 for proper drive coupling and correct as necessary.
- Check the connector between PS6-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary.
- PS6 I/O check, sensor check
- Control signal: FSCB J21-10 (ON)
- Location of electrical component: FS-540/FS-540SD 4-D
- M13 operation check
- Control signal: FSCB J21-1 to 4
- Location of electrical component: FS-540/FS-540SD 4-D
- Replace M13. (Part# A87HPPAD00)
- Replace FSCB. (Part# AAR5PPD401)