Trouble typePaddle motor’s drive malfunction
Trouble codeC1141
RankB
Detection timing<When FS-534 is installed>
The upper paddle homeposition detection sensor (PS14) is not blocked or unblocked even after the set period of time has elapsed while the FNS paddle motor (M5) is turning.
<When FS-535 is installed>
Even after a predetermined period of time has elapsed since the paddle motor (M16) starts operation, the lock signal is not set to L (turning).
Trouble isolationStaple
Relevant electrical parts<When FS-534 is installed>
• FNS paddle motor (M5)
• Upper paddle home position detection sensor (PS14)
• FS control board (FSCB)
<When FS-535 is installed>
• Paddle motor (M16)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M5-FSCB J4 for proper connection, and correct as necessary.
2Check the connector of M5 for proper drive coupling, and correct as necessary.
3Check the connector between PS14-FSCB J4 for proper connection, and correct as necessary.
4PS14 I/O check, sensor checkFSCB J4<B>-7 (ON)FS-534 13-C
5M5 operation checkFSCB J4<A>-5 to 8FS-534 12-C to D
6Replace M5 (Part# A3EPPP5500)
7Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M16-relay CN211-FSCB CN21 for proper connection, and correct as necessary.
2Check the connector of M16 for proper drive coupling, and correct as necessary.
3M16 operation checkFSCB CN21-7 to 14FS-535 7-L
4Replace M16 (Part# A11PM10200)
5FSCB ICP13 conduction check
6Replace FSCB (Part# A2Y1H10002)
Table of Contents