How Can We Help?

C1141 (bizhub C658/C558/C458)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

When FS-539 or FS-539SD is installed

Contents

Trouble typeC1141: FNS paddle motor drive malfunction (When FS-539 or FS-539SD is installed)
RankB
Trouble detection conditionThe upper paddle home sensor (PS14) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the FNS paddle motor (M5) is energized.
Trouble isolationStaple
Relevant electrical parts-FNS paddle motor (M5)
-Upper paddle home sensor (PS14)
-FS control board (FSCB)

Procedure

  1. Check the connector between M5-FSCB J4 for proper connection and correct as necessary.
  2. Check the connector of M5 for proper drive coupling and correct as necessary.
  3. Check the connector between PS14-FSCB J4 for proper connection and correct as necessary.
  4. PS14 I/O check, sensor check
    • Control signal: FSCB J4<B>-7 (ON)
    • Location of electrical component: FS-539/FS-539SD 15-C
  5. M5 operation check
    • Control signal: FSCB J4<A>-12 to 15
    • Location of electrical component: FS-539/FS-539SD 14-C
  6. Replace M5. (Part# A3EPPP5500)
  7. Replace FSCB. (Part# AAR4PP8201)

 When FS-540 or FS-540SD is installed

Contents

Trouble typeC1141: FNS paddle motor drive malfunction (When FS-540 or FS-540SD is installed)
RankB
Trouble detection conditionThe upper paddle home sensor (PS25) is not turned OFF (blocked) or ON (unblocked) even after the set period of time has elapsed while the FNS paddle motor (M9) is energized.
Trouble isolationStaple
Relevant electrical parts-FNS paddle motor (M9)
-Upper paddle home sensor (PS25)
-FS control board (FSCB)

Procedure

  1. Check the connector between M9-relay CN13B-FSCB J14 for proper connection and correct as necessary.
  2. Check the connector of M9 for proper drive coupling and correct as necessary.
  3. Check the connector between PS25-relay CN13B-FSCB J14 for proper connection and correct as necessary.
  4. PS25 I/O check, sensor check
    • Control signal: FSCB J14<B>-13 (ON)
    • Location of electrical component: FS-540/FS-540SD 16-K to L
  5. M9 operation check
    • Control signal: FSCB J14<B>-7 to 10
    • Location of electrical component: FS-540/FS-540SD 17-K to L
  6. Replace M9. (Part# A87HPPA600)
  7. Replace FSCB. (Part# AAR5PPD401)

L.3.8.23 (Link to the Field Service Manual)