C1143 (bizhub 754e/654e)
Contents
Trouble type | Leading edge paddle up/down motor’s malfunction | |
Trouble code | C1143 | |
Rank | B | |
Detection timing | <When FS-535 is installed> The leading edge paddle home sensor (PS16) is not blocked or unblocked even after the set period of time has elapsed after the leading edge paddle up/down motor (M18) is turned ON. | |
Trouble isolation | – | |
Relevant electrical parts | • Leading edge paddle up/down motor (M18) • Leading edge paddle home sensor (PS16) • FS control board (FSCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M18-relay CN243-FSCB CN24 for proper connection, and correct as necessary. | – | – |
2 | Check the connector of M18 for proper drive coupling, and correct as necessary. | – | – |
3 | Check the connector between PS16-relay CN243-FSCB CN24 for proper connection, and correct as necessary. | – | – |
4 | PS16 I/O check, sensor check | FSCB CN24-16 (ON) | FS-535 9-L |
5 | M8 operation check | FSCB CN24-17 to 20 | FS-535 9-L |
6 | Replace M18 (Part# A11PR72800) | – | – |
7 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.2.7 Finisher FS-535)
- Link to the layout drawings for related parts by each trouble code (S.38. C1143)