How Can We Help?

C1143 (bizhub 754e/654e)

You are here:

Contents

Trouble typeLeading edge paddle up/down motor’s malfunction
Trouble codeC1143
RankB
Detection timing<When FS-535 is installed>
The leading edge paddle home sensor (PS16) is not blocked or unblocked even after the set period of time has elapsed after the leading edge paddle up/down motor (M18) is turned ON.
Trouble isolation
Relevant electrical parts• Leading edge paddle up/down motor (M18)
• Leading edge paddle home sensor (PS16)
• FS control board (FSCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M18-relay CN243-FSCB CN24 for proper connection, and correct as necessary.
2Check the connector of M18 for proper drive coupling, and correct as necessary.
3Check the connector between PS16-relay CN243-FSCB CN24 for proper connection, and correct as necessary.
4PS16 I/O check, sensor checkFSCB CN24-16 (ON)FS-535 9-L
5M8 operation checkFSCB CN24-17 to 20FS-535 9-L
6Replace M18 (Part# A11PR72800)
7Replace FSCB (Part# A2Y1H10002)
Table of Contents