C1143 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C1143: Arm drive motor drive malfunction (When FS-540 or FS-540SD is installed) |
Rank | B |
Trouble detection condition | The arm home sensor (PS26) is not turned ON (unblocked) or OFF (blocked) even after the set period of time has elapsed while the arm drive motor (M8) is energized. |
Trouble isolation | – |
Relevant electrical parts | – Arm drive motor (M8) – Arm home sensor (PS26) – FS control board (FSCB) |
Procedure
- Check the connector between M8-relay CN13A-FSCB J14 for proper connection and correct as necessary.
- Check the connector of M8 for proper drive coupling and correct as necessary.
- Check the connector between PS26-relay CN13B-FSCB J14 for proper connection and correct as necessary.
- PS26 I/O check, sensor check
- Control signal: FSCB J14<B>-6 (ON)
- Location of electrical component: FS-540/FS-540SD 17-K to L
- M8 operation check
- Control signal: FSCB J14<A>-8 to 11
- Location of electrical component: FS-540/FS-540SD 18-K to L
- Replace M8.
- Replace FSCB.