How Can We Help?

C1143 (bizhub C554/C454)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeLeading edge paddle up/down motors malfunction
Trouble codeC1143
RankB
Detection timing<When FS-535 is installed>
The leading edge paddle home sensor (PS16) is not blocked or unblocked even after the set period of time has elapsed after the leading edge paddle up/down motor (M18) is turned ON.
Trouble isolation
Relevant electrical parts-Leading edge paddle up/down motor (M18)
-Leading edge paddle home sensor (PS16)
-FS control board (FSCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M18-relay CN243-FSCB CN24 for proper connection, and correct as necessary.
2Check the connector of M18 for proper drive coupling, and correct as necessary.
3Check the connector between PS16-relay CN243-FSCB CN24 for proper connection, and correct as necessary.
4PS16 I/O check, sensor checkFSCB CN24-16 (ON)FS-535 9-L
5M8 operation checkFSCB CN24-17 to 20FS-535 9-L
6Replace M18 (Part# A11PR72800)
7Replace FSCB (Part# A3EPPPBE01)
  • Link to the wiring diagram (N.3.10 FS-535)
  • Link to the layout drawings for related parts by each trouble code (S.42. C1143)

K3.6.29 (Link to the Field Service Manual)

Table of Contents