How Can We Help?

C1143 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeLeading edge paddle up/down motor’s malfunction
Trouble codeC1143
RankB
Detection timing<When FS-535 is installed>
The leading edge paddle home sensor (PS16) is not blocked or unblocked even after the set period of time has elapsed after the leading edge paddle up/down motor (M18) is turned ON.
Trouble isolation
Relevant electrical parts• Leading edge paddle up/down motor (M18)
• Leading edge paddle home sensor (PS16)FS control board (FSCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M18-relay CN243-FSCB CN24 for proper connection, and correct as necessary.
2Check the connector of M18 for proper drive coupling, and correct as necessary.
3Check the connector between PS16-relay CN243-FSCB CN24 for proper connection, and correct as necessary.
4PS16 I/O check, sensor checkFSCB CN24-16 (ON)FS-535 9-L
5M8 operation checkFSCB CN24-17 to 20FS-535 9-L
6Replace M18 (Part# A11PR72800)
7Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.29 (Link to the Field Service Manual)

Table of Contents