C1144 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C1144: Pre-eject drive motor malfunction (When FS-534 or FS-534SD is installed) |
Rank | B |
Trouble detection condition | -The pre-eject home sensor (PS21) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON. -The pre-eject away sensor (PS22) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON. |
Trouble isolation | – |
Relevant electrical parts | -Pre-eject drive motor (M9) -Pre-eject home sensor (PS21) -Pre-eject away sensor (PS22) -FS control board (FSCB) |
Procedure
- Check the connector between M9-relay CN7<A>-FSCB J13 for proper connection, and correct as necessary.
- Check the connector of M9 for proper drive coupling and correct as necessary.
- Check the connector between PS21-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary.
- Check the connector between PS22-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary.
- PS21 I/O check, sensor check
- Control signal: FSCB J12-6 (ON)
- Location of electrical component: FS-534 6-C
- PS22 I/O check, sensor check
- Control signal: FSCB J12-9 (ON)
- Location of electrical component: FS-534 6-C
- M9 operation check
- Control signal: FSCB J13-3 to 4
- Location of electrical component: FS-534 8-C to D
- Replace M9. (Part# A87GPP1500)
- Replace FSCB. (Part# A3EPPPBE01)
NOTICE
- Link to the wiring diagram (FS-534)
K.3.8.15 (Link to the Field Service Manual)