How Can We Help?

C1144 (bizhub C754/C654)

You are here:

Contents

Trouble typePre-eject drive motor malfunction (When FS-534 is installed)
Stacker plate drive motor malfunction (When FS-535 is installed)
Trouble codeC1144
RankB
Detection timing<When FS-534 is installed>
-The pre-eject home sensor (PS21) is not blocked or unblocked even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON.
-The pre-eject away sensor (PS22) is not blocked or unblocked even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON.
<When FS-535 is installed>
The stacker plate home sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed while the stacker plate drive motor (M17) is energized.
Trouble isolation
Relevant electrical parts<When FS-534 is installed>
-Pre-eject drive motor (M9)
-Pre-eject home sensor (PS21)
-Pre-eject away sensor (PS22)
-FS control board (FSCB)
<When FS-535 is installed>
-Stacker plate drive motor (M17)
-Stacker plate home sensor (PS11)
-FS control board (FSCB)

(2)ProcedureWhen FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M9-relay CN7<A>-FSCB J13 for proper connection, and correct as necessary.
2Check the connector of M9 for proper drive coupling, and correct as necessary.
3Check the connector between PS21-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary.
4Check the connector between PS22-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary.
5PS21 I/O check, sensor checkFSCB J12-6 (ON)FS-534 6-C
6PS22 I/O check, sensor checkFSCB J12-9 (ON)FS-534 6-C
7M9 operation checkFSCB J13-3 to 4FS-534 8-C to D
8Replace M9 (Part# A87GPP1500)
9Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M17-relay CN233-FSCB CN23 for proper connection, and correct as necessary.
2Check the connector of M17 for proper drive coupling, and correct as necessary.
3Check the connector between PS11-FSCB CN20 for proper connection, and correct as necessary.
4PS11 I/O check, sensor checkFSCB CN20-12 (ON)FS-535 12-D
5M17 operation checkFSCB CN23-19~20FS-535 13-L
6Replace M17 (Part# A2Y1R70300)
7FSCB ICP9 conduction check
8Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.30 (Link to the Field Service Manual)

Table of Contents