How Can We Help?

C1145 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble typeTrailing edge stopper motors malfunction
Trouble codeC1145
RankB
Detection timing<When FS-534 is installed>
The trailing edge stopper home position detection sensor (PS20) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M6) is turned ON.
Trouble isolation
Relevant electrical parts• Trailing edge stopper motor (M6)
• Trailing edge stopper home position detection sensor (PS20)
• FS control board (FSCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M6-FSCB J5 for proper connection, and correct as necessary.
2Check the connector of M6 for proper drive coupling, and correct as necessary.
3Check the connector between PS20-relay CN22-FSCB J5 for proper connection, and correct as necessary.
4PS20 I/O check, sensor checkFSCB J5-9 (ON)FS-534 9-K
5M6 operation checkFSCB J5-13 to 16FS-534 9-K
6Replace M6 (Part# A3EPPP5500 )
7Replace FSCB (Part# A3EPPPBE01)
  • Link to the wiring diagram (N.2.7 FS-534)
  • Link to the layout drawings for related parts by each trouble code (S.28. C1145)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.6.16