How Can We Help?

C1145 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeTrailing edge stopper motor’s malfunction
Trouble codeC1145
RankB
Detection timing<When FS-534 is installed>
The trailing edge stopper home position detection sensor (PS20) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M6) is turned ON.
<When FS-535 is installed>
The trailing edge stopper home sensor (PS22) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M19) is turned ON.The trailing edge stopper standby sensor/1 (PS23) is not blocked or unblocked even after the set period of time has elapsed after trailing edge stopper motor (M19) is turned ON.The trailing edge stopper standby sensor/2 (PS42) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M19) is turned ON.
Trouble isolation
Relevant electrical parts<When FS-534 is installed>
• Trailing edge stopper motor (M6)
• Trailing edge stopper home position detection sensor (PS20)
• FS control board (FSCB) <When FS-534 is installed>
<When FS-535 is installed>
• Trailing edge stopper motor (M19)
• Trailing edge stopper home sensor (PS22)
• Trailing edge stopper standby sensor/1 (PS23)
• Trailing edge stopper standby sensor/2 (PS42)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M6-FSCB J5 for proper connection, and correct as necessary.
2Check the connector of M6 for proper drive coupling, and correct as necessary.
3Check the connector between PS20-relay CN22-FSCB J5 for proper connection, and correct as necessary.
4PS20 I/O check, sensor checkFSCB J5-9 (ON)FS-534 9-K
5M6 operation checkFSCB J5-13 to 16FS-534 9-K
6Replace M6 (Part# A3EPPP5500)
7Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical components
1Check the motor and sensor connectors for proper connection, and correct as necessary.
2Check the connector of M19 for proper drive coupling, and correct as necessary.
3PS22 I/O check, sensor checkFSCB CN20-15 (ON)FS-535 13-D
4PS23 I/O check, sensor checkFSCB CN20-18 (ON)FS-535 13-D
5PS42 I/O checkFSCB CN20-9 (ON)FS-535 12-D
6M19 operation checkFSCB CN19-9 to 12FS-535 11-D
7Replace M19 (Part# A2Y1R70200)
8Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.31 (Link to the Field Service Manual)

Table of Contents