C1146 (bizhub 958/808)
Contents
Trouble type | C1146: Trailing edge stopper motor/R malfunction | |
Rank | B | |
Trouble detection condition | <When FS-537 or FS-537SD is installed> The trailing edge stopper home position detection sensor/R (PS7) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the trailing edge stopper motor/R (M11) is turned ON. | |
Trouble isolation | – | |
Relevant electrical parts | <When FS-537 or FS-537SD is installed> • Trail edge stopper motor/R (M11) • Trail edge stopper sensor/R (PS7) • FS control board (FSCB) |
Procedure
- Check the connector between M11-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary.
- Check the connector of M11 for proper drive coupling, and correct as necessary.
- Check the connector between PS7-relay CN4-relay CN3-FSCB J21 for proper connection and correct as necessary.
- PS7 I/O check, sensor check
- Control signal: FSCB J21-16 (ON)
- Location of electrical component: FS-537/FS-537SD 5-D
- M11 operation check
- Control signal: FSCB J21-17 to 20
- Location of electrical component: FS-537/FS-537SD 5-D
- Replace M11. (Part# A87HPPAD00)
- Replace FSCB. (Part# A87HPP9M01)
NOTICE
- Link to the wiring diagram (FS-537/FS-537SD)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.